Hermetically Sealed Cleanroom Systems – Doors, Windows & Pass-Throughs | Metrolabs Chennai
📍 Chennai, Tamil Nadu | Pan India 📞 9840931231 ✉ metrolabs1@gmail.com
Home Cleanroom Home Hermetically Sealed Systems
ISO 14644 · GMP · WHO · EU Annex 1

Hermetically Sealed
Cleanroom Systems
— Doors, Windows & Pass-Throughs

A cleanroom enclosure is only as effective as the integrity of its openings. Every door, window, and material transfer point is a potential breach in the controlled environment — a pathway for unfiltered air, particles, and microbial contamination to compromise your ISO class and GMP grade. Metrolabs supplies and installs the complete range of hermetically sealed cleanroom access and transfer systems engineered to maintain differential pressure, prevent cross-contamination, and sustain cleanroom classification at every opening.

Hermetic Doors Vision Panels Pass-Through Boxes Air Locks Sliding Doors ISO 3–8
Technical Quick-Reference
ISO Class RangeISO 3 – ISO 8
Door TypesSwing / Sliding / Auto / Bi-Parting
Frame MaterialGI / SS 304 / SS 316L
Seal SystemPerimeter brush + drop seals
Air Leakage< 1 m³/h at 4 Pa (Class 4)
Vision PanelDouble / Triple-glazed, flush-mounted
🔒
ISO 3–8
Class Range
🌊
<1m³/h
Air Leakage
📍
Pan-India
Install
🔒
Airtight Hermetic Seal Systems
🌊
Differential Pressure Maintained
👁
Flush-Mounted Vision Panels
🔄
UV Pass-Through Boxes
GMP / ISO 14644 / WHO
🔧
Turnkey Supply & Installation
Hermetic Cleanroom Door — Seal System Anatomy
PERIMETER BRUSH SEAL AUTOMATIC DROP SEAL VISION PANEL Double / Triple Glazed Flush-mounted, IP65 Handle CLOSER STAINLESS STEEL KICK PLATE +Pa Positive Pressure −Pa Lower Grade
🔒 Perimeter Brush Seal
Continuous brush seal on all four edges. Maintains <1 m³/h air leakage at 4 Pa differential.
🌳 Automatic Drop Seal
Floor-contact drop seal deploys automatically when door closes — zero gap at floor level.
👁 Vision Panel
Flush-mounted double or triple-glazed panel — zero particle-trapping rebate or frame.
⚙️ Auto-Closer
Hydraulic closer ensures door returns to full seal position without manual attention.
What Makes a System Hermetic?

Why Ordinary Doors Fail in Cleanrooms — and What Hermetic Systems Do Differently

A standard commercial door has gaps around every edge — at the head, the sides, and especially at the floor threshold. In a cleanroom, these gaps allow unfiltered air to flow between zones, destroying the pressure differential that prevents cross-contamination. A hermetic system eliminates every gap with engineered seal mechanisms.

🌊

Maintaining Differential Pressure

GMP cleanrooms operate on a positive pressure cascade — Grade A at the highest pressure, flowing through B, C, D to corridor. Every door must maintain this differential even when partially ajar. Hermetic doors with brush perimeter seals and automatic drop seals achieve Class 4 air leakage (<1 m³/h at 4 Pa) to sustain the cascade.

🔒

Preventing Particle Ingress

Even a 1mm gap at the base of a conventional door allows 50,000+ particles per cubic metre of unfiltered corridor air to enter the cleanroom during each transit. A hermetic automatic drop seal eliminates this gap completely, extending to the floor surface the instant the door closes.

🔜

Interlocking for Airlock Control

Pharmaceutical airlocks require that only one door can be open at any time — enforced by an electro-mechanical door interlock system. Hermetic interlocked doors prevent simultaneous opening, ensuring the pressure buffer zone is maintained between cleanroom grades at all times.

🔄

Material Transfer Without Zone Breach

Static and dynamic pass-through boxes allow materials, samples, and supplies to be transferred between cleanroom grades without any person or unfiltered air crossing the zone boundary — with UV-C decontamination options for sterile-grade material transfer.

Hermetic System Products

Six Hermetically Sealed Cleanroom System Products

Metrolabs supplies and installs the complete range of hermetic access and transfer systems — each engineered to maintain cleanroom integrity at every type of opening:

🔒

Hermetic Single & Double Swing Doors

Single and double leaf hermetic cleanroom doors with perimeter brush seals, automatic hydraulic closers, and automatic drop floor seals. Available in steel (CRCA painted), SS 304, and SS 316L for sterile-grade facilities. Single-glazed or double-glazed flush vision panels as specified. Suitable for ISO Class 5–8 cleanroom zones with manual or automatic operation.

ISO 5–8Swing / Single / DoubleDrop SealSS 304 / 316L

Automatic Hermetic Sliding Doors

Motorised sliding hermetic doors for high-traffic cleanroom areas where hands-free operation is essential — reducing the risk of surface contact contamination. Pneumatic or electro-mechanical drive with perimeter brush seals and sensor activation. Bi-parting option for wide openings. Fail-safe operation with battery backup and manual override. Suitable for ISO Class 6–8 pharmaceutical and food cleanrooms.

Auto SlidingHands-FreeBi-PartingFail-Safe
🔜

Interlocked Airlock Door Systems

Electro-mechanically interlocked door pairs for pharmaceutical airlocks, gowning rooms, and buffer zones between GMP grades. Controller enforces single-door-open protocol at all times — the second door cannot open until the first is fully closed and sealed. Traffic light indicators (red / green), audio alerts, and data logging for GMP audit trails. Critical for Grade A/B aseptic suite access control.

Electro-interlockAirlockAudit LogGrade A/B
👁

Flush-Mounted Vision Panels & Windows

Flush-mounted double or triple-glazed vision panels installed with zero-frame-rebate system — the glass is flush with the wall surface, eliminating particle-trapping ledges, frames, and recesses. Anti-static glass coating prevents electrostatic particle attraction on cleanroom-facing surfaces. Available as fixed panels, sliding vision panels, and heated double-glazed units for cold room cleanrooms. Suitable for all ISO classes.

Flush-MountedZero RebateAnti-StaticDouble / Triple Glazed
🔄

Static & Dynamic Pass-Through Boxes

Material transfer chambers mounted through cleanroom walls for passing items between zones without personnel crossing the boundary. Static pass-throughs with interlocked hinged doors for routine material transfer. Dynamic pass-throughs with HEPA-filtered unidirectional airflow and UV-C irradiation for decontamination of incoming materials in Grade A / ISO 5 aseptic suites. All units stainless steel interior with pharmaceutical-grade silicone seals.

Static / DynamicHEPA AirflowUV-C DeconSS Interior
🔌

Rapid Roll-Up & High-Speed Doors

High-speed roll-up cleanroom doors for high-traffic controlled environments where a conventional swing or slide door would cause excessive air movement or production disruption. Open in <1 second, close automatically after passage — minimising the duration of any cleanroom boundary opening. Brush seals on all four sides of the door frame maintain hermetic integrity in closed position. Used in pharmaceutical packaging lines, food production, and large cleanroom bay access.

<1 sec OpenAuto-CloseHigh TrafficBrush Sealed
Technical Features

Engineering the Hermetic Seal — Key System Features

Every component of a hermetic cleanroom door and window system is precision-engineered to eliminate air leakage pathways:

🌳

Automatic Drop Floor Seal

Mechanically actuated seal drops to the floor surface the instant the door closes — driven by the door leaf’s own closing momentum. Eliminates the floor gap that allows particle and pressure leakage at the base of all conventional doors. Retracted automatically when the door opens to prevent dragging across the floor.

🔒

Perimeter Brush + Compression Seals

Continuous brush seal on three sides (head and both jambs) provides primary air leakage resistance. A secondary compression seal on the door stop provides back-up containment, achieving combined Class 4 air leakage classification (<1 m³/h at 4 Pa pressure differential).

🔜

Electro-Mechanical Interlock Controller

Monitors the open/closed state of each door in an airlock pair via magnetic reed switches. Prevents simultaneous opening through electro-magnetic locking. Provides traffic light indicator status, audio alert on violation attempt, and tamper-evident data log with timestamp for GMP audit trails.

👁

Flush-to-Wall Vision Panel System

Purpose-engineered flush-mount frame system secures the vision panel glass flush with the cleanroom wall surface — no stepped rebate, no ledge, no particle-trapping frame profile on the cleanroom-facing side. Fully cleanable with standard disinfectants. Available in heated glass version for cold room environments.

Anti-Static & ESD-Safe Glass Options

Vision panels in electronics and semiconductor cleanrooms are specified with anti-static ITO-coated glass that permanently dissipates electrostatic charge — preventing particle attraction to the glass surface and protecting sensitive components from electrostatic discharge through the door panel.

Technical Specifications
ISO Class RangeISO 3 – ISO 8
Air Leakage ClassClass 4 (<1 m³/h at 4 Pa)
Door Frame MaterialGI / SS 304 / SS 316L
SS 316L FinishRa < 0.5 μm electro-polished
Seal SystemBrush + compression + drop seal
Vision Panel GlazingDouble / Triple-glazed (4+12+4mm)
Vision Panel Flush Tolerance±0.5 mm flush with wall face
Pass-Through InteriorSS 304 / SS 316L
Dynamic PTB AirflowH14 HEPA (99.995% @ 0.3μm)
UV-C Decontamination254 nm, >15 min cycle
Interlock Data Log21 CFR Part 11 compliant
High-Speed Door Open Time< 1 second
Standards & Compliance
WHO GMPEU Annex 1ISO 14644NABLUS-FDA cGMP21 CFR Part 11FSSAI / HACCP
GMP Cleanroom Pressure Cascade — Why Every Door Must Be Hermetic
Grade A
+20 Pa
ISO Class 5 — Filling zone / Aseptic work
Highest positive pressure. Every door opening must be hermetically sealed to prevent any lower-grade air ingress during transit.
Grade B
+15 Pa
ISO Class 7 — Background to Grade A
5 Pa differential to Grade A maintained by interlocked airlock doors. Only one door open at any time.
Grade C
+10 Pa
ISO Class 8 — Secondary processing / Preparation
5 Pa below Grade B. Hermetic doors prevent backflow of Grade C air into Grade B zones during transit.
Grade D
+5 Pa
Controlled Non-Classified — Gowning / Support
Lowest cleanroom grade. Airlock with hermetic doors separates this zone from uncontrolled corridor.
Corridor
0 Pa
Uncontrolled corridor — Atmospheric pressure
No HEPA filtration. Every hermetic door seal prevents uncontrolled air from entering the cleanroom envelope.
Key Principle
Air always flows from higher-pressure zones to lower-pressure zones. Hermetic door seals (<1 m³/h at 4 Pa) ensure this flow is controlled by HVAC systems — not by door gaps.
Why Hermetic Systems Are Essential

The Four Critical Functions of a Hermetically Sealed Opening

🌊

Sustaining Differential Pressure

Hermetic seals limit air leakage to <1 m³/h, allowing HVAC systems to maintain the designed pressure differential between zones — the single most important mechanism preventing cross-contamination between GMP grades.

🔌

Preventing Cross-Contamination

Every gap in a cleanroom boundary is a contamination pathway. Hermetic seals block the movement of particles, microorganisms, allergens, and active pharmaceutical ingredients between adjacent zones during personnel and material transit.

🔜

Enforcing Access Control

Interlocked airlock systems ensure the pressure buffer zone between cleanroom grades is never compromised by simultaneous opening — a fundamental GMP design requirement for Grade A/B aseptic manufacturing facilities.

📋

Generating Audit Evidence

Interlocked door controllers with 21 CFR Part 11-compliant data logging generate timestamped records of every door event — providing documented evidence that the airlock protocol was followed during critical pharmaceutical operations.

Where Hermetic Systems Are Installed

Every Regulated Cleanroom Application

💊

Pharmaceutical Manufacturing

Interlocked hermetic doors for Grade A/B/C/D GMP suites — WHO, EU Annex 1, and US-FDA inspection compliant with 21 CFR Part 11 audit log.

🎁

Aseptic & Sterile Suites

SS 316L hermetic doors with dynamic pass-through boxes and UV-C decontamination for injectable fill-finish and aseptic compounding areas.

🏥

Hospital Operating Theatres

Auto-sliding hermetic doors for operating suites, NICU, isolation rooms, and hospital sterile processing (CSSD) departments.

🧪

Microbiology & Biosafety Labs

Interlocked hermetic access systems for BSL-2 and BSL-3 labs maintaining containment integrity at every access and transfer point.

🍽️

Food & Beverage Production

High-speed hermetic doors for high-traffic food production lines — hands-free auto-sliding or roll-up for FSSAI and HACCP-regulated production areas.

Electronics & Semiconductor

ESD-safe hermetic doors with anti-static vision panels for ISO 4–7 semiconductor fabrication and precision electronics assembly cleanrooms.

🧮

Biotech & Cell Therapy Labs

Pass-through boxes with UV-C and HEPA dynamic airflow for biosecure material transfer in cell therapy, mRNA, and gene therapy manufacturing facilities.

🔬

NABL & Research Facilities

Flush vision panels and static pass-through boxes for NABL-accredited testing labs and controlled-environment research facilities requiring documented containment.

Why Metrolabs?

Hermetic Systems vs. Standard Commercial Doors

Standard commercial fire or security doors are sometimes specified for cleanroom use to reduce costs — but they lack every engineering feature that makes a door hermetic. The performance difference is substantial:

🔒

Complete Seal System — All Four Edges

Metrolabs hermetic doors seal all four edges simultaneously — perimeter brush seal on three sides and an automatic drop seal at the floor. Standard doors have gaps on all four sides that cannot be eliminated without specialist retrofitting.

👁

Flush Vision Panels — No Ledges

Our flush-mount vision panel system eliminates the stepped rebate that accumulates particles on standard framed windows — the ledge that auditors cite as a contamination risk in every facility using off-the-shelf framed glazing.

🔧

Single Supplier for All Openings

Metrolabs supplies and installs hermetic doors, sliding doors, interlocked airlocks, vision panels, pass-through boxes, and high-speed doors — all under a single contract, ensuring full compatibility between all system components.

📋

IQ Documentation at Handover

Installation Qualification records including air leakage test results, interlock function verification, vision panel flush measurement records, and pass-through decontamination cycle data — all delivered as part of the standard project handover package.

Hermetic vs. Standard Commercial Door

Performance Factor Standard Door Hermetic System
🌊 Air leakage
∼50–100 m³/h
✓ <1 m³/h
🌳 Floor seal
✕ Gap always present
✓ Auto drop seal
👁 Vision panel
🔴 Rebated frame ledge
✓ Flush-mounted
🔜 Interlock system
✕ Not available
✓ Electro-mechanical
✅ GMP compliance
✕ Fails inspection
✓ Fully compliant
📋 IQ documentation
✕ None
✓ Full IQ package
🔄 Pass-through
✕ Not applicable
✓ Static & dynamic
Regulatory Standards

Hermetic Systems Required by Every Major Cleanroom Regulatory Framework

💊

WHO & EU GMP

WHO GMP and EU Annex 1 (2022) for sterile manufacturing explicitly require airlocks between different GMP grades, controlled-access systems with pressure monitoring, and airtight construction of all cleanroom boundaries — hermetic door systems are the primary engineering solution.

WHO GMP · EU Annex 1
🏭

ISO 14644 Cleanroom Standard

ISO 14644-4 cleanroom design requires controlled access systems that maintain the design air cleanliness class — specifying that doors, windows, and pass-throughs must not compromise the differential pressure cascade between cleanroom zones.

ISO 14644-4
📋

21 CFR Part 11 (US-FDA)

US-FDA 21 CFR Part 11 requires electronic records and electronic signatures for pharmaceutical manufacturing operations. Interlock door controllers with compliant data logging generate the documented evidence that airlock protocols were followed during critical operations.

21 CFR Part 11

NABL & ISO/IEC 17025

NABL accreditation for testing laboratories requires controlled-access facilities with documented containment integrity. Hermetic pass-through boxes and vision panels allow work to be observed and materials transferred without compromising laboratory containment during NABL assessments.

NABL · ISO 17025
Seal Your Cleanroom

Ready to Seal Every Opening in Your Cleanroom?

Contact Metrolabs for a free consultation. Our cleanroom engineers will assess every door, window, and material transfer requirement in your facility — specifying the hermetic system that maintains your ISO class and GMP grade at every opening, with full IQ documentation at handover.

🔒
Hermetic Doors — Swing, Sliding, Interlock & High-Speed
Class 4 air leakage <1 m³/h. Brush + drop seal system.
👁
Flush-Mounted Vision Panels
Zero rebate, anti-static, double/triple glazed.
🔄
Static & Dynamic Pass-Through Boxes
SS interior, HEPA airflow, UV-C decontamination options.
📋
Full IQ Documentation at Handover
Air leakage test records, interlock verification, 21 CFR Part 11 audit log.

🔒 Request a Free Hermetic System Consultation

Consultation Requested!

Our hermetic systems team will contact you within 24 working hours.

Immediate: 9840931231